GSM-204-423
Suggested RF configurations
31st Oct 01
Installation & Configuration: Horizon
macro
outdoor
68P02902W03-A
CONTROLLED INTRODUCTION
Inst. 3–53
Configuration
for 3 cabinet
sector 4/4/4
Figure 3-30 shows a suggested configuration, using three Horizon
macro
cabinets, for sector 4/4/4 with dual stage duplexed combining filter and hybrid
combining unit.
CABINET 2
CABINET 3
CABINET 1
(master)
Figure 3-30 Three cabinet sector 4/4/4 with DDF and HCU