User's Manual Part 2

Test Set Calibration continued
PRELIMINARY
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
3-62
Setting Cable Loss Values
Cable loss values for the TX and RX test cable configurations are
normally set by accomplishing automatic cable calibration with use of
the applicable test equipment. The resulting values are stored in the cable
loss files. The cable loss values can also be set/changed manually.
Cable loss values must be manually entered in the LMF
database if manual cable calibration was performed.
Failure to do this will result in inaccurate BTS calibration
and reduced site performance.
CAUTION
Prerequisites
S Logged into the BTS
Table 3-29: Setting Cable Loss Values
Step Action
1 Click on the Util menu.
2 Select Edit > Cable Loss > TX or RX. A data entry popup window will appear.
3 Click on the Add Row button to add a new channel number. Then click in the Channel # and Loss
(dBm) columns and enter the desired values.
4 To edit existing values click in the data box to be changed and change the value.
5 To delete a row, click on the row and then click on the Delete Row button.
6 Click on the Save button to save displayed values.
7 Click on the Dismiss button to exit the window. Values that were entered/changed after the Save
button was used will not be saved.
NOTE
S If cable loss values exist for two different channels the LMF will interpolate for all other channels.
S Entered values will be used by the LMF as soon as they are saved. You do not have to logout and
login.
3