User's Manual Part 2

Test Equipment Setup
08/01/2001
3-47
1X SCt4812ET Lite BTS Optimization/ATP
PRELIMINARY
Connecting Test Equipment to
the BTS
All test equipment is controlled by the LMF through an IEEE488/GPIB
bus. The LMF requires each piece of test equipment to have a factory set
GPIB address. If there is a communications problem between the LMF
and any piece of test equipment, verify that the GPIB addresses have
been set correctly as follows:
S Power meter address should be 13
S Communications test set should be 18
The following test equipment is required to perform optimization,
calibration and ATP tests:
S CDMA LMF
S Communications test set model supported by the CDMA LMF
S Power meter model supported by the CDMA LMF (required when
using the HP 8921A/600 and Advantest R3465 test sets)
S Nonradiating transmit line termination load
S Directional coupler and inline attenuator
S RF cables and adapters
Refer to Table 3-22 for an overview of connections for test equipment
currently supported by the CDMA LMF. In addition, see the following
figures:
S Figure 3-15 and Figure 3-16 show the test set connections for TX
calibration
S Figure 3-17 and Figure 3-18 show the test set connections for
optimization/ATP tests
Supported Test Equipment
Optimization and ATP testing may be performed using the following test
equipment:
S CyberTest
S Advantest R3465 and HP437B or Gigatronics Power Meter
S HewlettPackard HP 8935
S HewlettPackard HP 8921 (W/CDMA and PCS Interface (1.9 GHz))
and HP437B or Gigatronics Power Meter
S Spectrum Analyzer (HP8594E) optional
S Rubidium Standard Timebase optional
To prevent damage to the test equipment, all transmit (TX)
test connections must be through a 30 dB directional
coupler plus a 20 dB in-line attenuator for both the 800
MHz and 1.9 GHz BTSs.
CAUTION
3