User's Manual Part 2

InService Calibration continued
08/01/2001
H-25
1X SCt4812ET Lite BTS Optimization/ATP
PRELIMINARY
Table H-6: InService Calibration
Step Action
4 Add the spectrum analyzer power delta to the TX Cable Loss.
Click Util > Edit > Cable Loss > TX.
Add the value computed in Table H-4, Table H-5, or Table H-3 to the TX Cable Loss.
NOTE
Be sure to include the sign of the value. The following examples are included to show the mathematics
and do not represent actual readings:
Example: 5.65 dBm + 0.55 dBm = 6.20 dBm
Example: 5.65 dBm + (0.29 dBm) = 5.36 dBm
Example: 5.65 dBm + 0.55 dBm = 5.10 dBm
Example: 5.65 dBm + (0.29 dBm) = 5.94 dBm
5 Input the Coupler Loss for the TX tests:
Click Util > Edit > Coupler Loss > TX from the menu bar at the main window.
Enter the appropriate coupler loss for the target carrier(s) by referring to the information taken at
the time of BTS installation.
Click the Save button.
Click the Dismiss button to close the window.
To view the coupler loss file, click Util > Examine > Coupler Loss.
6 Input the Coupler Loss for the RX tests:
Click Util > Edit > Coupler Loss > RX from the menu bar at the main window.
Enter the appropriate coupler loss for the target carrier(s) by referring to the information taken at
the time of BTS installation.
Click the Save button.
Click the Dismiss button to close the window.
To view the couper loss file, click Util > Examine > Coupler Loss.
7 If it was not previously done, have the CBSC operator put the redundant BBX OOS_MANUAL.
! CAUTION
Be sure to download OOS devices only. Loading inservice devices takes them OUT OF SERVICE
and can result in dropped calls.
The code file version numbers must match the version numbers on the other cards in the frame. If the
numbers do not match, the site may go OUT OF SERVICE.
NOTE
Be sure to include the redundant BBX in steps 8, 9, and 10.
. . . continued on next page
H