User's Manual Part 2
Module Front Panel LED Indicators and Connectors – continued
PRELIMINARY
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
6-34
PWR/ALM LED
LENS
(REMOVABLE)
ACTIVE LED
PWR/ALM ACTIVE
Figure 6-4: MCC24 Front Panel LEDs and LED Indicators
PWR/ALM
OFF - operating normally
ON - briefly during powerĆup and during failure
ąconditions
ACTIVE
LED OPERATING STATUS
RAPIDLY BLINKING - Card is codeĆloaded but
ąnot enabled
SLOW BLINKING - Card is not codeĆloaded
ON - card is codeĆloaded and enabled
ą(INS_ACTIVE)
COLOR
GREEN
RED
RED
ON - fault condition
SLOW FLASHING (alternating with green) - CHI
ąbus inactive on powerĆup
An alarm is generated in the event of a failure
FW00224
LPA Shelf LED Status
Combinations
LPA Module LED
Each LPA module is provided with a bi–color LED on the ETIB module
next to the MMI connector. Interpret this LED as follows:
S GREEN — LPA module is active and is reporting no alarms (Normal
condition).
S Flashing GREEN/RED — LPA module is active but is reporting an
low input power condition. If no BBX is keyed, this is normal and
does not constitute a failure.
S Flashing RED — LPA is in alarm.
6