User's Manual Part 3
BTS Redundancy/Alarm Testing – continued
Mar 2001
3-89
68P09253A61
SCt4812T CDMA BTS Optimization/ATP
DRAFT
Miscellaneous
Alarm/Redundancy Tests
Follow the steps in Table 3-48 to verify alarms reported by the master
GLI are displayed via the alarm monitor if a BTS frame module failure
occurs.
Table 3-48: Miscellaneous Alarm Tests
Step Action
1 Select Util>Alarm Monitor to display the alarm monitor window.
2 Perform the following to verify fan module alarms:
• Unseat a fan module (see Figure 3-21 or Figure 3-22).
• Observe an alarm message was reported via the MGLI (as displayed on the alarm monitor).
• Replace fan module and verify the alarm monitor reports that the alarm clears.
• Repeat for all other fan modules in the BTS frame.
NOTE
Follow Step 3 for Starter Frames and Step 4 for Expansion Frames.
3 Starter Frames Only:
Perform the following to verify MPC module alarms.
• Unseat MPC modules (see Figure 3-19) one at a time.
• Observe that an alarm message was reported via the MGLI as displayed on the alarm monitor.
• Replace the MPC modules and verify the alarm monitor reports the alarm clears.
4 Expansion Frames Only:
Perform the following to verify EMPC module alarms.
• Unseat EMPC modules (see Figure 3-19) one at a time
• Observe that an alarm message was reported via the MGLI as displayed on the alarm monitor.
• Replace the EMPC modules and verify the alarm monitor reports that the alarm clears.
5 If equipped with AMR redundancy, perform the following to verify AMR module redundancy/alarms.
• Unseat AMR 2 (see Figure 3-19).
• Observe that an alarm message is reported via the MGLI (as displayed on the alarm monitor).
• Repeat Steps 1 through 3 and/or 4.
• Replace the AMR module and verify the alarm monitor reports that the alarm clears.
• Unseat AMR 1 and observe an alarm message was reported via the MGLI (as displayed on the alarm
monitor).
• Replace the AMR module and verify the LMF reports the alarm has cleared.
NOTE
All PWR/ALM LEDs should be GREEN at the completion of this test.
3