BTS Redundancy/Alarm Testing continued
Mar 2001
3-89
68P09253A61
SCt4812T CDMA BTS Optimization/ATP
DRAFT
Miscellaneous
Alarm/Redundancy Tests
Follow the steps in Table 3-48 to verify alarms reported by the master
GLI are displayed via the alarm monitor if a BTS frame module failure
occurs.
Table 3-48: Miscellaneous Alarm Tests
Step Action
1 Select Util>Alarm Monitor to display the alarm monitor window.
2 Perform the following to verify fan module alarms:
Unseat a fan module (see Figure 3-21 or Figure 3-22).
Observe an alarm message was reported via the MGLI (as displayed on the alarm monitor).
Replace fan module and verify the alarm monitor reports that the alarm clears.
Repeat for all other fan modules in the BTS frame.
NOTE
Follow Step 3 for Starter Frames and Step 4 for Expansion Frames.
3 Starter Frames Only:
Perform the following to verify MPC module alarms.
Unseat MPC modules (see Figure 3-19) one at a time.
Observe that an alarm message was reported via the MGLI as displayed on the alarm monitor.
Replace the MPC modules and verify the alarm monitor reports the alarm clears.
4 Expansion Frames Only:
Perform the following to verify EMPC module alarms.
Unseat EMPC modules (see Figure 3-19) one at a time
Observe that an alarm message was reported via the MGLI as displayed on the alarm monitor.
Replace the EMPC modules and verify the alarm monitor reports that the alarm clears.
5 If equipped with AMR redundancy, perform the following to verify AMR module redundancy/alarms.
Unseat AMR 2 (see Figure 3-19).
Observe that an alarm message is reported via the MGLI (as displayed on the alarm monitor).
Repeat Steps 1 through 3 and/or 4.
Replace the AMR module and verify the alarm monitor reports that the alarm clears.
Unseat AMR 1 and observe an alarm message was reported via the MGLI (as displayed on the alarm
monitor).
Replace the AMR module and verify the LMF reports the alarm has cleared.
NOTE
All PWR/ALM LEDs should be GREEN at the completion of this test.