User's Manual Part 3

InService Calibration continued
Mar 2001
I-13
SCt4812T CDMA BTS Optimization/ATP
DRAFT
Follow the procedure in Table I-4 to perform the InService Calibration.
Table I-4: InService Calibration
Step Action
* IMPORTANT
Perform this procedure after test equipment has been allowed to warmup and stabilize for a minimum
of 60 minutes.
1 Set up the LMF for InService Calibration:
Start the LMF by doubleclicking the LMF icon on the Windows desktop.
Click Options>LMF Options from the menu bar at the login screen.
Check only the applicable spectrum analyzer check box on the Test Equipment tab.
Ensure that the GPIB address is 18.
Uncheck any other other equipment that is selected.
Click the Apply button.
Select the BTS Options tab in the LMF Option window.
Check the InService Calibration check box.
Click the Apply button.
Click the Dismiss button to close the LMF Option window.
2 Login to the target BTS:
Select the target BTS icon.
Click the Login button at the login screen.
3 Measure the Cable Loss using the Cable Calibration function:
Click Util>Cable Calibration from the menu bar at the main window.
Set the desired channel(s) and select TX and RX CABLE CAL at the cable calibration pop up
window.
Click the OK button to perform cable calibration.
Follow the onscreen instructions to complete the cable loss measurement.
NOTE
The measured value is input automatically to the cable loss file.
To view the cable loss file, click Util>Examine>Cable Loss.
. . . continued on next page