User's Manual
Cabinet Cabling
– continued
DRAFT
SC
TM
4812ET RF and Power Cabinet Hardware Installation Manual
Apr 2001
V04.03
98
Installation Procedure
Table 5-9 details the step–by–step procedure on installing the RGPS
cabling.
Table 5-9: RGPS Cable Install Procedure
Step Action
1 Route the twisted pair cable through the previously installed conduit to the RF Cabinet I/O area, and
to the punch block through the rubber boot in the floor of the I/O area (See Figure 5-6). Refer to
Figure 5-1 for the recommended locations.
NOTE
The rubber boot is sized to seal a cable with an outer diameter of either 1/4” or 1/2”, if a different
sized cable is used heat/cold shrink or other means may be required to ensure a good seal. A tie wrap
or hose clamp must be used to ensure a good seal around the cables at the boot.
2 Connect the RGPS pairs from the cable to the punch block (using only the recommended 110 style
punch tool CGDS237744 or equivalent) per the pin call–outs in Table 5-10.
3 Strain relief the cable by tie wrapping it to the punch block mounting bracket as shown in Figure 5-5
The RGPS cable is comprised of 6 twisted pairs of wires.
For proper RGPS operation, each BLACK wire in this
cable is unique and must be paired with it’s proper mate.
NOTE
Punch Block for the Remote GPS (RGPS)
Table 5-10: Punch Block for the Remote GPS
Punch Block
Pin Number
Signal Name Wire Color
42T GPS_POWER_1+ BLUE
42R GPS_POWER_1– BLACK/BLUE
43T GPS_POWER_2+ YELLOW
43R GPS_POWER_2– BLACK/YELLOW
44T GPS_RX+ WHITE
44R GPS_RX– BLACK/WHITE
45T GPS_TX+ GREEN
45R GPS_TX– BLACK/GREEN
46T TDR+ RED
46R TDR– BLACK/RED
47T GPS_1pps+ BROWN
47R GPS_1pps– BLACK/BROWN
5