User's Manual
Cabinet Cabling
– continued
DRAFT
SC
TM
4812ET RF and Power Cabinet Hardware Installation Manual
Apr 2001
V04.03
88
Table 5-1: BTS Cable Descriptions and Part Numbers
Cable
Label
DescriptionPart Number
F Supplied with Power
Cabinet
3064377A10
DC Power Cable (Quantity = 3), #2/0 AWG INS WELD cable (Black); 3650
mm (12 ft) length.
G Customer Supplied AC Power cable, Maximum Cable Size of 300 kcmil.
NOTE
The Power Cabinet is rated at 130 Amps (100 Amps continuous / 130 Amps
non–continuous, in the range of 208–240V AC) see Table 5-32 for details.
Maximum cable size that can be accommodated is 300 kcmil. Cabling sizing
should be determined by Local Electrical Codes, using 90°C rated
conductors, and derating for 50°C operation. Motorola recommends not less
than #2/0 AWG (#1 BSWG; 50 mm
2
) copper for buried/raceway cables to
the power pedestal, with an associated power pedestal breaker size of 150
Amps for one Power Cabinet.
H Customer Supplied Ground Cable (Quantity 1 per cabinet), #3 BSWG (#2 AWG; 35 mm
2
)
I Customer Supplied Antenna RF Cable, 50 Ohm coaxial, male N–type connector on one end,
customer to determine other end.
J
Supplied in Kit
STAN4000A
RF GPS Cable, 1/2 inch coaxial, length=50 ft. Two male N–type connectors,
one end loose (to be field terminated after routing of cable through I/O
boot).
If lengths greater than 50 ft. are required, cable style and length should be
determined by site configurations. Maximum loss <4.5 dB @ 1575 MHz for
all cabling and connections between the GPS antenna and the RF Cabinet.
NOTE
A 1/2 inch cable “pigtail” should always be used to exit the cabinet before
transitioning to a larger cable. This will ensure a proper seal at the rubber
I/O boot. It is suggested that the supplier cable be cut to the desired length to
achieve this.
K CGDS3155A038
LFR Cable, 100 Ohm, 24 AWG, shielded twisted pair, 91.5 m (300 ft.) One
9–pin subminiature D connector and one 5–pin circular connector.
L 3086622H01
Options Power Cable, # 14 AWG; 820 mm (2.7 ft.) length
NOTE
This options power cable is shipped installed in sites that are factory
equipped with CSU options.
* Cable – 12 conductor, shielded, twisted pair, 22 AWG, solid. Insulation – PVC (–40 to +60°C)
** Cable – 12 conductor, shielded, twisted pair, 22 AWG, solid. Insulation – FEP Teflon (–40 to +125°C)
Plenum rated
5