User's Manual
Cabinet Cabling
– continued
Apr 2001
V05.03
87
SC
TM
4812ET RF and Power Cabinet Hardware Installation Manual
DRAFT
Cable descriptions
Table 5-1 lists the RF and Power Cabinet cable description and part
numbers. The cable label is used as a reference for all the cabling
procedures and diagrams.
Table 5-1: BTS Cable Descriptions and Part Numbers
Cable
Label
Part Number Description
A Customer Supplied
T1 Span Line(s) and Modem Cable #24 or #22 AWG, 26-wire, shielded
twisted 13 pair, 100-Ohm, solid wire; nominal line rate at 1.544 Mbit/s.
For E1: use 120–Ohm twisted pairs; nominal line rate at 2.048 Mbit/s
NOTE
The modem lines pair (2–wire) and Span Line pairs can be run on a separate
cables if more appropriate for the installation.
B Customer Supplied
Alarm (Customer I/O) Cable #24 or #22 AWG, 32-wire, shielded twisted 16
pair, 100-Ohm, solid wire.
T472AA RGPS Cable and Antenna Package, 50 Ft. Cable*
T472AB RGPS Cable and Antenna Package, 125 Ft. Cable**
T472AC RGPS Cable and Antenna Package, 250 Ft.Cable**
T472AD RGPS Cable and Antenna Package, 500 Ft.Cable**
T472AE RGPS Cable and Antenna Package, 1000 Ft.Cable**
T472AF RGPS Cable and Antenna Package, 2000 Ft.Cable**
C
T472AG RGPS Cable Only, 50 Ft. Cable*
T472AH RGPS Cable Only, 125 Ft. Cable**
T472AJ RGPS Cable Only, 250 Ft.Cable**
T472AK RGPS Cable Only, 500 Ft.Cable**
T472AL RGPS Cable Only, 1000 Ft.Cable**
T472AM RGPS Cable Only, 2000 Ft.Cable**
T472AN RGPS Antenna Only
D
Supplied with Power
Cabinet
3086039H17
Power Cabinet Alarm/Control Cable, 12–wire, shielded twisted 6 pair, solid
wire: 3650 mm (12 ft.) length.
NOTE
A longer alarm/Control cable (P/N 3086039H16) 10950 mm (36 ft.) is
available to order if needed.
E Supplied with Power
Cabinet
3064377A09
DC Power Cable (Quantity = 3), #2/0 AWG INS WELD cable (Red); 3650
mm (12 ft) length.
. . . continued on next page