4812ET RF and Power Cabinet Hardware Installation Manual
DRAFT
Conduits that are preinstalled in a concrete pad below
grade must be capped at the time of conduit installation to
prevent rainwater from collecting in the conduit.
CAUTION
If a precast concrete foundation pad is used, the pad should
be in place before the cables are installed. This will avoid
an unsafe condition caused by personnel reaching under a
pad, as it is lowered, to feed cable through the pad
openings.
WARNING
Connection Materials
This section defines connection materials and specifications and may
vary depending on sitespecific requirements. If in doubt, contact
Motorola Cellular Support Center (telephone number is found in the
Foreword of this manual).
Concrete Pad and Ground
System Installation
The following procedure describes the concrete pad ground system
installation. The following steps are meant to serve as a guideline and
can be impacted by the local codes of the installation site location.
Materials Needed:
CADWELD Joints
812 ground wire to ground rod joints (for 26 cabinets)
4 rebar joints
1 ground wire to rebar joint
Ground Rods - 812 5/8 Diameter, 2438 mm (96) long ground
rods (for 26 cabinets)
Framing Materials This list of materials is used to form the pad.
No. 6644 wire mesh, or 9.5 mm (3/8) rebar, sized to fit the pad
Concrete (Must conform to ASTMC94, specification for ready mix
concrete)
It is recommended that the concrete pad maintain a
minimum thickness of 102 mm (4 inches) or the length of
the anchor bolt to be used, whichever is greater.
NOTE