Site Preparation continued
DRAFT
SC
TM
4812ET RF and Power Cabinet Hardware Installation Manual
Apr 2001
44
It may not be necessary or desirable to run the transmission
lines in any conduit at all. In this case the transmission
lines should be protected from falling objects (i.e., ice,
etc.) or from being stepped on.
NOTE
Table 2-6: Heliax Cable Loss and Minimum Bend Radii
Heliax Motorola Part
dB loss per meter dB loss per foot Min. bend radius
Heliax
Cable
Motorola Part
No.
@ 1 GHz @ 2 GHz @ 1 GHz @ 2 GHz Metric U.S.
RG 142 CGDSRG142BU .49 .66 .15 .20 10 mm .4
3/8 LDF N/A .115 .167 .035 .051 95 mm 33/4
1/2LDF SGDN4232A .0768 .1132 .0234 .0345 125 mm 5
1/2 FSJ4 N/A .119 .177 .0363 .0541 13.75 mm 1.25
7/8LDF SGDN4234A .0430 .0646 .0131 .0197 250 mm 10
11/4LDF SGDN4235A .0317 .0476 .00967 .0145 380 mm 15
15/8LDF SGDN4233A .0269 .0410 .00819 .0125 510 mm 20
NOTE
As an additional rule of thumb, allow 0.1 dB additional loss for each connection point.
Table 2-7: Number of wires in Conduit
Conduit
Foam Heliax Trade Size (Cable Type LDF)
Conduit
Trade Size
9.5 mm (3/8) 12.7 mm (1/2) 21.4 mm (7/8) 31.8 mm (11/4) 41.3 mm (15/8)
2 5 2 1
21/2 7 3 1
3 11 5 3
4 19 9 5 1 1
6 20 20 12 3 2
* IMPORTANT
The values listed above were calculated based on the percent of conduit crosssection filled and recommended
limits set forth by Andrew Corporation. These limits are based on common conditions or proper cabling and
alignment of conductors where the length of pull and the number of bends are within reasonable limits. It
should be recognized that for certain conditions a larger size conduit or a lessor fill should be considered.
Power Cabinet AC Power Connection
208240 VAC Flexible Liquid Tight Conduit is recommended.
2