User's Manual

Site Preparation
continued
Apr 2001
V02.03
37
SC
TM
4812ET RF and Power Cabinet Hardware Installation Manual
DRAFT
Table 2-2: Approximate Weight of SC 4812ET BTS
# of Sectors
Carriers
1
RF Cabinet
2
Power Cabinet
3
Total Weight Weight/Area Total Weight Weight/Area
3 570 kg (1260 lbs) 563 kg/m
2
(0.8 psi) 1015 kg (2240 lbs) 1002 kg/m
2
(1.84 psi)
6 610 kg (1340 lbs) 602 kg/m
2
(0.85 psi) 1206 kg (2660 lbs) 1192 kg/m
2
(1.7 psi)
9 644 kg (1420 lbs) 636 kg/m
2
(0.91 psi) 1400 kg (3080 lbs) 1383 kg/m
2
(2.0 psi)
12 680 kg (1500 lbs) 671 kg/m
2
(0.95 psi) 1590 kg (3500 lbs) 1571 kg/m
2
(2.2 psi)
NOTE
1
To obtain this number, multiply the number of sectors and the number of carriers present (i.e., 3 sector, 3
carrier is 9 sectorcarriers)
2
Assumes 12 DRDCs present in cabinet
3
Assumes 4 hours of battery backup and maximum battery weight of 41 kg (90 lbs) each.
SC 4812ET RF FRU
Configuration
SC 4812ET FRU Configurations for Duplexed sites are described in
Table 2-3 (see page 38).
SC 4812ET FRU Configurations for NonDuplexed sites are described
in Table 2-4 (see page 39).
2