DRAFT
SC
TM
4812ET RF and Power Cabinet Hardware Installation Manual
Apr 2001
V06.03
120
Check that all FRU modules and doors are closed and latched.
Organize any items (manuals, materials, etc.) left on site and place
them in a location specified by the site manager.
Fill out Installation Completion
Checklist
After the site is cleaned up, fill out the installation completion checklist
(see Table 6-1) and make any necessary copies. Make copies of this
checklist as needed.
Date Hardware Installation Completed:
Site:
Master BTS Cabinet Serial Number(s):
Expansion BTS Cabinet Serial Number(s):
Checklist Completed By:
Checklist Reviewed By:
Table 6-1: Installation Completion Checklist
Status No. Item Notes
1 Cabinets are bolted down with mounting bolts
properly torqued.
2 Each cabinet has its own earth ground that is
connected to a proper site grounding system.
Ground MUST be connected first.
3 AC power cabling completed and checked by an
electrician and the AC breakers are OFF.
4 DC power cabling between Power and RF cabinets
is installed and the DC breakers are OFF.
5 Battery breakers are OFF.
6 RX RF cables installed.
7 TX RF cables installed.
8 RF connections are properly sealed with tape.
9 Span and Modem line cables installed.
10 RF cabinet alarm cable is installed.
. . . continued on next page
6