Installation Instructions
BTS Configuration – continued
DEC 2000
7-17
SCt300 BTS Hardware Installation, ATP and FRU Procedures
PRELIMINARY
Establishing an MMI
Communication Session
For those procedures which require MMI communication between the
CDMA LMF and the BTS, follow the procedures in Table 7-6 to initiate
the communication session.
If an LMF session is in progress, logout of the LMF prior
to establishing an MMI communication session. Refer to
steps 1 and 2 of the “Remove LMF” procedure in
Table 7-38.
NOTE
Table 7-6: Establishing MMI Communication
Step Action
1 Connect the CDMA LMF computer to the BTS. Refer to the “Connecting the LMF to the BTS”
procedure in this chapter.
2 Start the named HyperTerminal connection for MMI sessions by double clicking on its Windows
desktop shortcut.
3
NOTE
If a Windows desktop shortcut was not created for the MMI connection, access the connection from
the Windows Start menu by selecting:
Programs > Accessories > Hyperterminal > HyperTerminal >
<Named HyperTerminal
Connection (e g MMI Session)>
C
onnec
ti
on
(
e.g.,
MMI
S
ess
i
on
)
>
Once the connection window opens, establish MMI communication with the BTS FRU by pressing
the CDMA LMF computer Enter key until the prompt identified in the applicable procedure is
obtained.
Every command is entered at the SC300> prompt unless otherwise specified.
Simulated LMF session
You must start a simulated LMF session when you enter MMI
commands. Enter the following command at the MMI prompt to
simulate an LMF link:
sndtype 0xa178
You should enter this command at the beginning of every MMI
Communication Session.
Programming Customer
Operating Channel
A non–volatile database containing the default channel and default
power level of the site must be programmed. The default channel is the
customer operating channel for this site. The default power level must
be set to –50 dBm which will be overwritten by the MM/OMCR when
the site comes on–line.
7