Installation Instructions

Test Equipment and LMF Connection – continued
DEC 2000
7-11
SCt300 BTS Hardware Installation, ATP and FRU Procedures
PRELIMINARY
Advantest R3465
front panel
Advantest R3465
rear panel
BNC
“T”
CONNECTIONS DEPICTED BY HEAVY BOLD LINES ARE
STATIONARY AND SHOULD REMAIN INSTALLED DURING
TEST EQUIPMENT TRANSPORT FROM SITE TO SITE.
19.6608 MHZ REFERENCE
2 SECOND REFERENCE
GPIB
CONNECTOR
FROM EVEN
SEC/SYNC IN
Figure 7-9: R3465 Communications Test Set Timing Signal Detail (Advantest R3465)
THE FWD B AND RFL B
CONNECTORS ARE
NOT PRESENT ON THE
PICOCELL
BTS DIAGNOSTIC ACCESS
AREA (MICROCELL SHOWN)
7