Installation Instructions

Remote GPS Replacement Procedure – continued
PRELIMINARY
SCt300 BTS Hardware Installation, ATP and FRU Procedures
DEC 2000
9-20
Install the replacement RGPS head
Follow the steps in Table 9-12 to install the replacement RGPS head.
Refer to Figure 9-6.
Table 9-12: Install the Replacement RGPS Head
Step Action
1 Connect the cable connector of the replacement RGPS head to the RGPS cable connector. Secure
the connection by tightening the spinning connector flange.
2 Feed the cable slack into the RGPS head end of the mounting pipe/conduit.
3 Grasp the RGPS head with one hand and the pipe/conduit with the other hand.
Be careful not to cross–thread the fitting on the RGPS head, screw the pipe/conduit into the head.
Hand tighten only!
4 Tighten the pipe/conduit mounting hardware until the pipe/conduit is securely mounted.
Figure 9-6: RGPS Head Replacement
SITE I/O INTERFACE
UNSCREW PIPE, PULL CABLE THROUGH AND
DISCONNECT CABLE CONNECTOR
CABLE CONNECTOR LOCATED
INSIDE PIPE
9