Installation Instructions

Shut Down & Restore BTS Signaling – continued
PRELIMINARY
SCt300 BTS Hardware Installation, ATP and FRU Procedures
DEC 2000
9-10
Table 9-3: Restore Signaling Operations
Step Action
5
* IMPORTANT
In this step, use the values recorded in step 3 of the shut down signaling functions table to answer
the prompts for the EDIT SECTOR REDIRECT command; except for record type enter 2.
NOTE
This step shows the entry of initial standard values which is consistent with the original example;
except record type must be 2. Your entries may be different.
Restore the values of all redirect parameters by entering the following command at the prompt:
omc–000000>EDIT SECTOR–<bts#><sector#>
REDIRECT !
The system will prompt you to enter each command parameter one at a time. Answer the prompts
in the following order (Note that the following specified values are consistent with the original
example. Yours may be different):
<accolc0>
Enter N,
<accolc1>
Enter N,
...
<accolc15>
enter N
<returniffail>
, enter N
<recordtype>
, enter 2
<expectedsid>
enter 0
<expecteds
i
d>
, en
t
er
0
<ignorecdma>
, enter N
<sysordering>
, enter CUSTOM
<rotatetimer>
, enter 4
The system will display the command that will be sent. Verify the command syntax.
omc–000000>Accept [yes/no]?
Enter Y to accept the command.
6 View the status of the sector signaling redirect parameters to verify that the sector is ready for
maintenance.
omc–000000>DISPLAY SECTOR–<bts#><sector#> REDIRECT
Ensure that the values in the system display response match the values input by the operator in
step 5 (see example below).
Access Overload Class Redirect Flags ROTATE
CARRIER ID RETURN 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 TIMER RECORD EXP IGNORE SYS
(bts–sector–carrier) IF FAIL 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 (SEC) TYPE SID CDMA ORDERING
–––––––––––––––––––– ––––––– – – – – – – – – – – – – – – – – ––––– –––– ––– –––– ––––––––
CARRIER–1–1–1 N N N N N N N N N N N N N N N N N 4 2 0 N CUSTOM
. . . continued on next page
9