Installation Instructions
Test Cable Calibration – continued
PRELIMINARY
SCt300 BTS Hardware Installation, ATP and FRU Procedures
DEC 2000
7-40
Automated Cable Calibration
Procedure
This procedure calibrates the cables that will be used for BTS testing.
Follow the steps in Table 7-24 to calibrate the test cables.
Prerequisites
1. Test equipment has been connected as shown in Figure 7-11.
2. Power for the test equipment and GPIB box has been turned on.
3. LMF has been started and BTS has been logged into.
Procedure
Follow the steps in Table 7-24 to calibrate the test cables. Refer to
Figure 7-14.
A 30 dB attenuator is used for Microcell (high power)
BTSs. A 10 dB attenuator is used for Picocell BTSs.
NOTE
Table 7-24: Automated Cable Calibration
Step Action
1 Click on the Util>Cable Calibration menu item.
2 Select one of the following options in the Cable
Calibration menu: TX and RX CABLE CAL, TX
CABLE CAL, or RX CABLE CAL.
N
O
TE
NOTE
Normally the option TX and RX CABLE CAL is used so
both the TX and RX cable configurations are calibrated. The
TX CABLE CAL and RX CABLE CAL options are used
only if one of the cable configurations needs to be calibrated.
3 Click the OK button. A Directions pop–up is displayed for
each step of the cable calibration.
4 Follow the directions displayed for each step. A status report
window is displayed with the results of the cable calibration.
5 Click on OK to close the status report window.
7