User Manual
CSM System Time – GPS & HSO Verification – continued
PRELIMINARY 2
SC 4812ET BTS Optimization/ATP – CDMA LMF
July 1999
3-34
GPS Initialization/Verification
Follow the steps outlined in Table 3-21 to connect to CSM–1 installed in
the C–CCP shelf, verifying that it is functioning normally.
Table 3-21: GPS Initialization/Verification
Step Action
1 To verify that Clock alarms (0000), Dpll is locked and has a reference source, and
GPS self test passed messages are displayed within the report, issue the following MMI
command
bstatus
– Observe the following typical response:
CSM Status INS:ACTIVE Slot A Clock MASTER.
BDC_MAP:000, This CSM’s BDC Map:0000
Clock Alarms (0000):
DPLL is locked and has a reference source.
GPS receiver self test result: passed
Time since reset 0:33:11, time since power on: 0:33:11
. . . continued on next page
3