User Manual

Preparing the LMF – continued
PRELIMINARY 2
SC 4812ET BTS Optimization/ATP – CDMA LMF
July 1999
3-14
code Folder
The code folder contains the binary files used to load code into the
devices. A unique binary code file is required for each device type in the
BTS to be supported with the LMF. Current version code files for each
supported device created in this folder from the LMF CD ROM as part
of the LMF installation/update process. Figure 3-7 shows an example of
the file naming syntax for a code load file.
Figure 3-7: Code Load File Name Syntax Example
bbx.ram.bin–0600
Device Type
Hardware bin number
If this number matches
the bin number of the
device, the code file will
automatically be used
for the download*
* The device bin number can be determined by using the
Status function after logging into a BTS. If the device
does not have a bin number, one of the following default
numbers must be used:
GLI=0100
LCI=0300
MCC=0C00
BBX=0600
BDC=0700
CSM=0800
TSU=0900
LPAC=0B00
MAWI=0D00
If a code file with the correct version and bin numbers is not found, a file
selection window appears.
3