Pre–Power–up Tests – continued
PRELIMINARY 2
SC 4812ET BTS Optimization/ATP – CDMA LMF
July 1999
2-16
Table 2-18: DC Power Pre–test (RF Cabinet and Power Cabinet)
Step Action
7 Set the 8 LPA breakers ON by pushing them IN one at a time. Repeat step 3 after turning on each
breaker.
A typical response is that the ohmmeter will steadily climb in resistance as capacitors charge,
stopping at approximately 500
Ω..
8 Plug all LPAs and EBA fan module into associated plugs in the chassis one at a time. Repeat step 3
after connecting each LPA and EBA fan module.
A typical response is that the ohmmeter will steadily climb in resistance as capacitors charge,
stopping at approximately 500
Ω..
Disconnect Ohm meter after all tests are successfully completed.
9 Seat the heat exchanger, ETIB, and Options breaker one at a time. Repeat Step 3.