Power Cabinet Initial Power Up – continued
July 1999
2-13
SC 4812ET BTS Optimization/ATP – CDMA LMF
PRELIMINARY 2
Rectifier Over Temperature
Alarm
This is the J8 on the rear of the DMAC itself, this is not
connector J8 on the connector bulkhead at the rear of the
cabinet.
NOTE
Table 2-16 gives instructions on testing the battery over temperature
alarm system.
Table 2-17: Rectifier Over Temperature Alarm
Step Action
1 Remove the J8 link on the rear of the DMAC.
NOTE
This is the J8 on the rear of the DMAC itself, this is not connector J8 on the connector bulkhead at
the rear of the cabinet.
2 Verify that RECTIFIER OVERTEMP LED (red) is illuminated. Contacts on K1 and K2 change
states (K1 now closed and K2 open).
3 Verify that the LMF has reported an alarm condition. Alarm condition will be reported as BTS–26
contact.
4 Reinstall J8 connector and verify that all alarm conditions have cleared. K1 and K2 should now be
in their normal states (K1 open and K2 closed).
5 This completes the system tests of the SC 4812ET Power Cabinet.