Basic Troubleshooting – Span Control Link
PRELIMINARY 2
SC 4812ET BTS Optimization/ATP – CDMA LMF
July 1999
5-28
Span Problems (No Control
Link)
Table 5-25: Troubleshooting Control Link Failure
Step Action
1 Verify the span settings using the span_view command
on the active master GLI2 MMI port. If these are set
correctly, verify the edlc parameters using the
show
command. Any alarms conditions indicate that the span is
not operating correctly.
– Try looping back the span line from the DSX panel
back to the Mobility Manager (MM) and verify that
the looped signal is good.
– Listen for control tone on appropriate timeslot from
Base Site and MM.
2 If no traffic channels in groomed MCC24s (or in whole
C–CCP shelf) can process calls, verify that the ISB
cabling is correct and that ISB A and ISB B cables are not
swapped.