User Manual

Transmit & Receive Antenna VSWR – continued
PRELIMINARY 2
SC 4812ET BTS Optimization/ATP – CDMA LMF
July 1999
3-82
Equipment Setup – Advantest
Test Set
Follow the steps outlined in Table 3-47 to set up test equipment required
to measure and calculate the VSWR for each antenna.
Table 3-47: VSWR Measurement Procedure – Advantest Test Set
Step Action ADVANTEST
1 For manual VSWR testing using external directional coupler, refer to Figure 3-26.
Connect the communications test set RF OUT port to the input port of the directional coupler.
Connect the INPUT port of the communication test set to the forward port on the directional
coupler. Terminate the forward port with a 50 ohm load.
Connect the RF short to the directional coupler output port.
2 Preform the following to instruct the calibrated test set to generate a CDMA RF carrier (RVL call)
with all zero longcode at the assigned RX frequency at –10 dBm.
Push the ADVANCE Measurement key.
Push the CDMA Sig CRT menu key.
Push the FREQ Entry key; set RF Gen Freq to center frequency of actual CDMA carrier between
1930–1990 MHz for TX and 1850–1910 MHz for RX.
Push the LEVEL Entry key; set to 0 dBm (by entering 0 and pushing the –dBm key).
Verify that ON is active in the Output CRT menu key.
Verify that OFF is active in the Mod CRT menu key.
Push the CW Measurement key.
Push the FREQ Entry key.
Push the more 1/2 CRT menu key.
Set Preselect CRT menu key to 3.0G.
Push the Transient Measurement key.
Push the Tx Power CRT menu key.
Push the LEVEL entry key (set to 7 dBm by entering 7 and pushing the the dBm key).
Set Avg Times CRT menu key to ON. Set to 20 (by entering 20 and pushing the Hz ENTER
key).
Push the REPEAT Start key to take the measurement.
3 Record the Burst Power display on the communications analyzer and Note as P
S
for reference.
4 Install the antenna feedline to the output port of the directional coupler.
5
Push the Auto Level Set CRT menu key.
Push the REPEAT Start key to take the measurement.
6 Record the Burst Power on the communications analyzer and Note as P
A
level for reference.
Record the difference of the two readings in dBm.
. . . continued on next page
3