Test Set Calibration – continued
PRELIMINARY 2
July 1999
3-57
SC 4812ET BTS Optimization/ATP – CDMA LMF
Table 3-29: Cable Calibration
ActionStep
4 Click OK. Follow the direction displayed for each step. A status report window will be displayed
with the results of the cable calibration (refer to Figure 3-15).
Calibrating TX Cables Using a
Signal Generator and
Spectrum Analyzer
Follow the procedure in Table 3-30 to calibrate the TX cables using the
signal generator and spectrum analyzer. Refer to Figure 3-23 for a
diagram of the signal generator and spectrum analyzer.
Table 3-30: Calibrating TX Cables Using Signal Generator and Spectrum Analyzer
Step Action
1 Connect a short test cable between the spectrum analyzer and the signal generator.
2 Set signal generator to 0 dBm at the customer frequency of 1840–1870 MHz band for Korea PCS and
1930–1990 MHz band for North American PCS.
3 Use spectrum analyzer to measure signal generator output (see Figure 3-23, “A”) and record the value.
4 Connect the spectrum analyzer’s short cable to point “B”, as shown in the lower portion of the
diagram, to measure cable output at customer frequency (1840–1870 MHz for Korea PCS and
1930–1990 MHz for North American PCS) and record the value at point “B”.
5 Calibration factor = A – B
Example: Cal = –1 dBm – (–53.5 dBm) = 52.5 dB
NOTE
The short cable is used for calibration only. It is not part of the final test setup. After calibration is
completed, do not re-arrange any cables. Use the equipment setup, as is, to ensure test procedures use
the correct calibration factor.