User Manual
1X UBS Macro B T S FRU P ack et B T S shutdown procedures
Procedure 3 -2 Shutdown site signaling functions procedure for a pack et B T S
At the OMCR
1
Open a CLI window . Refer to Accessing OMCR CLI window on page 3- 3 .
2
• The recommended shutdown technique is to redirect subscribers to
another site/carrier and then wait for any active calls to terminate before
locking/disabling the BTS .
• REDIRECT prevents future calls from being originated on the targeted
resource.
P erform one of the following:
• T o redirect subscribers and then wait for any active calls to terminate before disabling
the BTS , go to step 3 .
• T o lock/disable the BTS when there is no concern for redirecting subscribers and
waiting for any active calls to terminate, perform step 23 through step 26 only .
3
The REDIRECT command is used to invoke the REDIRECT2 command which is then
used to redirect subscribers to a different CDMA carrier frequency . REDIRECT2 is
the preferred command if an alternate CDMA carrier is available.
Enter the following command at the prompt to display the status of the BTS signaling redirect
parameters for all carriers equipped for the BTS:
omc-000000> DISPLAY BTS-<bts#> REDIRECT
4
Record the values shown in the system display response resulting from performing step 3 .
These values are needed to answer the prompts for the EDIT BTS REDIRECT
command when restoring signaling operations at the end of the maintenance or
upgrade procedure.
Continued
68P09283A64 -3 3 -5
FOA SEP 2007