UBS Macro B T S Product Ov erview Chapter 1: Ov erview
DMI (Digital Module Internal) module
The DMI contains two main components: a controller board and at least one modem board (i.e.,
1X CDMA or EV -DO). The controller board provides interfaces for up to two modem boards (i.e.,
1X CDMA, EV -DO , or a combination of both). A DMI can be upgraded with a second modem
board depending upon the configuration required at the BTS .
In the forward direction (BTS to Mobile), the DMI terminates the backhaul control and bearer
connections from the S SI, processes the bearer and control data then routes the baseband
data to the XMI for conversion/RF modulation and transmission over the air interface to the
subscriber .
In the reverse direction (Mobile to BTS), the XMI receives the subscriber transmission over
the air interface. The XMI demodulates the received RF signal and converts it to baseband
data. The received baseband data is routed to the DMI for processing and generation to the
associated control and bearer data for transmission to the network via the S SI.
External interfaces on the DMI include the following:
+27 V DC (nominal) power input
T wo S SI interfaces
T wo XMI interfaces
The controller board provides all of the DMI external interfaces as well as interfaces for two
modem boards. The controller is made up of the following functions: Site Processor (SPROC),
Synchronization, Interworking (protocol termination), DMI baseband processing, XMI interfaces
and S SI interface.
The DMI controller board also contains an Oven Controlled Crystal Oscillator (OCX O) that
is synchronized to the BTS system timing established/sourced by the E -GPS or Remote GPS
(RGPS) head. The OCX O also provides the MSO function. In the event that the GPS system
timing signal (i.e., E -GPS or RGPS or sync -sharing) is lost, the DMI controller can select the
MSO as a backup synchronization source for maintaining BTS system timing for up to 8 hours
PDU (Power Distribution Unit)
The PDU is the central power distribution point for the UBS Macro BTS frame. It contains input
power feeds that connect to the +27 V DC power output of one of the following:
Optional –48 V DC PSM (P ower Supply Module) shelf
Optional 220 V AC PSM shelf
Customer supplied external +27 V DC power source
The PDU houses circuit breakers/power connectors for +27 V DC power distribution to each of
the following UBS Macro BTS frame subsystems:
XMIs
DMIs
S SIs
Accessories
The PDU also contains bulk capacitance to stabilize the internal bus voltage to facilitate
subsystem hot -swap and absorb surge energy .