Product Info
XMI (T r ansceiv er Module Internal) Module Chapter 7: XMI R eplacement Procedures
Alarms will be reported during the replacement procedure.
The XMI is not “hot swappable”.
Table 7 -1 FRU R eplacement Conditions
FRU
What to Shut Down...
XMI
From the OMCR, lock the XMI being removed. Then shut down
XMI DC input power .
Required items
Manpower
• T wo people are required to lift, carry , or handle the XMI module.
Documents
•
1X UBS Macro BTS Optimization/A TP
manual.
Tools
• T25 TORX bit.
• T orque driver .
• XMI removable handle with two M5 screws.
• Heat protective gloves for handling/touching a “HOT" XMI.
Replacement Unit
• 800 MHz XMI FRU assembly with removable XMI handle attached (Motorola model
SGTF4194)
• 1.9 GHz XMI FRU assembly with removable XMI handle attached (Motorola model
STWG4000)
7 -8 68P09283A64 -3
FOA SEP 2007