User Manual
P ower Distribution Unit (PDU) Equipment Identication Chapter 1: Ov erview
Power Distribution Unit (PDU) Equipment Identication
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■
■
PDU I/O Panels
Figure 1 -12 shows I/O connectors on the front panel of the UBS Macro BTS PDU . This figure
shows connector and circuit breaker locations and usage details.
Figure 1 -13 shows I/O cable and connectors on the rear panel of the UBS Macro BTS PDU . This
figure shows cable/connector locations and brief cabling details.
Figure 1 -12 PDU front panel detail
ti-cdma-05913.eps
HAZARD OF
ELECTRIC SHOCK
WITH PANEL REMOVED
LIVE TERMINALS
CAUTION
20 20 20
90
+27 V DC
Power Output
Connector Row
NOTES:
1. Equipment shown is typical. The actual equipment appearance may vary slightly.
2. The power output connector and associated circuit breaker are an intergral unit.
The power output connector is always positioned directly above the associated circuit breaker.
3. Usually only power output connectors and circuit breakers are populated when the associated XMI, DMI, SSI or ACC
is equipped. The actual equipage is customer dependent.
Cicuit
Breaker
Row
90 A
1
1 2
32 4
5
20 A 20 A 20 A
XMI SSI
Accessories
1 2
DMI
3 4
1 -42 68P09283A64 -3
FOA SEP 2007