Specifications

1X UBS Macro B T S Optimization/A TP TX Code Domain P ower/Noise Floor Acceptance T est
TX Code Domain Power/Noise Floor Acceptance Test
Code Domain Power Test
F or each sector/antenna under test, the Pilot Gain is set to 383 LSB. All channel elements under
test are configured to generate Orthogonal Channel Noise Source (OCNS) on standard pattern -
only 9 channels where the 6 Traffic channels (TCH) can be anywhere across the code domain
The maximum number of channel elements (CEs) to be tested at any one time is 32 (32 odd
W alsh codes). If more than 32 CEs exist, then multiple sets of measurements are made; so all
channel elements are verified on all sectors.
Sector -carrier power output is set to 43 dBm as measured at the TX OUT connector .
CD_PILOT_RA TIO: -6.5dB to -7.5dB
CD_P AGING_RA TIO: -6.8dB to -7.8dB
CD_SYNC_RA TIO: -12.8dB to -13.8dB
CD_TRAFFIC_ON_MAX_RA TIO: -9.8dB to -10.8dB
CD_TRAFFIC_ON_MIN_RA TIO: -9.8dB to -10.8dB
CD_TRAFFIC_OFF_MAX_RA TIO: -27dB (none)
Refer to Figure 4 -6 .
If using Advantest test equipment, Code Domain T est MUST be configured in RC -1
mode.
See Procedure 4 -5 to perform this test.