Specifications

1X UBS Macro B T S Optimization/A TP Alarms T esting
Procedure E -4 Customer Alarm Input V erication (Continued)
16
Click on the Set Alarm Relays menu item.
17
Click on Unequipped .
A status report window displays the results of the action.
18
Click on OK to close the status report window .
19
Refer to Figure E -2 and sequentially short the ALARM
A connector CA IN 1 through CA IN 12 pins together .
Sequentially short the ALARM B connector
CA IN 13 through CA IN 24 pins together .
No alarms should be displayed.
20
Load data to the Controller to reset the alarm relay conditions according
to the NEC file.
Pin and Signal Information for Alarm Connectors
T able E -1 and T able E -2 lists the pins, wire color codes, and signal names.
Table E -1 Connector Pinout for Cable T IP 1–12 OP 1–4
Pin Name
Recommended W ire Color for Cable
1 CA IN 1
White/Blue
2 CA IN 2
White/Orange
3 CA IN 3
White/Green
4 CA IN 4
White/Brown
5
CA IN 5
White/Gray
6 CA IN 6
Red/Blue
7
CA IN 7
Red/Orange
8 CA IN 8
Red/Green
9 CA IN 9
Red/Brown
10 NC
NA
11 CA NO 1
Black/Blue
12 CA NO 2
Black/Orange
13 CA NC 2
Black/Green
14 CA NO 3
Black/Brown
15 CA NO 4
Black/Gray
16 CA NC 4
Y ellow/Blue
17 CA IN 10
Y ellow/Orange
18 CA IN 11
Y ellow/Green
19 CA IN 12
Y ellow/Brown