Specifications
1X UBS Macro B T S Optimization/A TP Ba y Lev el Offset Calibr ation
Single–sided BLO Checkbox
Another option that appears in the pull–down menu is Single–sided BLO . Normally valid
BLO values are some value plus–or–minus some offset. Single–sided BLO spec is >–3.5 dB.
Double–sided BLO spec is –1.5 +/– 2.0 dB. T o get the more stringent conditions, the operator
checks Single–sided BLO when calibrating non -redundant transceivers. Single–sided BLO
carries the likelihood of more failures. This option should only be used by experienced CFEs.
The T ests > TX > TX Calibration... menu window has a T est P attern pull–down menu. This
menu has the following choices.
• Pilot (default) – performs tests using a pilot signal only . This pattern should be used when
running in–service tests. It requires the DMIs to do the test.
• Standard – performs the tests using pilot, synch, paging and six traffic channels.
• CDFPilot – performs the tests using the pilot signal, however , the gain is specified in the
NEC file. Advanced users may use CDFPilot to generate a Pilot pattern using the value
specified by the Pilot Gain parameter in the NEC file instead of a predetermined value.
• CDF – performs the tests using pilot, synch, paging and six traffic channels, however , the
gain for the channel elements is specified in the NEC file. Advanced users may use NEC to
generate a standard pattern. Instead of using the values specified by IS–97, the settings
for the following NEC parameters are used:
PilotGain
PchGain
SchGain
NomGain1W ay
68P09283A63 -5 E -9
A UG 2007 FOA