Specifications

1X UBS Macro B T S Optimization/A TP Agilent E7495A/B T est Equipment Setup
Procedure D -2 E7495A/B P ower Sensor Calibr ation (Continued)
3
Zero the power meter by doing the following:
1. Press the Zero softkey .
2. Press the Continue softkey .
4
Calibrate the power meter by doing the following:
1. Press Ref CF .
2. Enter the reference cal factor , reading it off the label on the power sensor head.
3. Press Calibrate .
4. Connect the power sensor (see Figure D -2 ).
5. Press Continue .
6. Press Cal Factor .
7. Enter the cal factor from the label on the power sensor head. Select a cal factor that is
within the operating frequency of the base station being calibrated.