Specifications
1X UBS Macro B T S Optimization/A TP Conguring Backhaul
Span configuration (ubsSpan)
• Span type: T1
• Frame type: ESF , Extended ...
• Coding type: B8ZS , Bipolar 8–...
• T ermination type: TX131, 131 to 2...
• Link alarm set threshold (bit errors / second): 30
• Link alarm set duration (seconds): 10
• Link alarm clear threshold (bit errors / second): 30
• Link alarm clear duration (seconds): 10
• Link removal threshold (bit errors / second): 75
• Link removal duration (seconds): 10
• Link recovery threshold (bit errors / second): 75
• Link recovery duration (seconds): 10
Procedure 5 -2 R esetting Backhaul P ar ameters to their Default V alues
1
Go to the LMF Configure Backhaul Screen.
2
Click on the Show Advanced box at the bottom of the screen. A full list of
backhaul parameters will now be displayed. See Figure 5-2
3
Change the values in the entry boxes to align with the default values noted
above.
4
Click on the OK button.
68P09283A63 -5 5 -5