Specifications
1X UBS Macro B T S Optimization/A TP Conguring Backhaul
Figure 5 -1 Congure Backhaul Basic Screen
ti-cdma-06184.eps
Procedure 5 -1 Fr actional Span Backhaul Congur ation Procedure
1
Go to the LMF Configure Backhaul Screen. See Figure 5-1
The default value for both the
LcpNcpNegRetryInt
and the
PPPK eepAliveMsg
parameters is 1000 ms. If the UBS will use
satellite backhaul, the value for these parameters must be set to
2000 ms.
2
If the UBS will use Fractional Span backhaul, click on the F ractional Span box.
The Start DS0 and End DS0 boxes will now accept operator - entered values.
3
Enter the starting DS0 and ending DS0 intended for Span 1 into the
appropriate boxes. The LMF will configure Span 1, which is sufficient to
allow the cutover to succeed. Span 2 will be configured from the OMC-R
after cutover .
4
Select the correct span type, frame type, coding type and span equalization
from the pull-down menus in the Span Configuration section.
5
Click on the OK button.
68P09283A63 -5 5 -3
FOA A UG 2007