Specifications

Conguring Backhaul Chapter 5: Lea v e the Site
Conguring Backhaul
Before disconnecting the LMF and test equipment, the span backhaul must be configured to
allow the UBS to communicate with the OMC -R.
Introduction
General
This section allows the Cellular Field Engineers (CFEs) to pre -configure the UBS backhaul
parameters prior to cutting over the UBS . It also contains information on how to make
adjustments to individual backhaul parameters.
Conguring the UBS Backhaul
Prior to BTS cutover , some span configuration and connection parameters must be set to match
the type of backhaul chosen for the particular BTS . These parameters can be checked and
changed if required using the LMF Configure Backhaul Basic Screen. W ith these values set
correctly , the OMC -R should be able to establish communications with the BTS . In the event
that communication between the OMC -R and the BTS is lost and cannot be re -established, the
LMF Configure Backhaul Advanced Screen can be used to restore the backhaul configuration
to default values. See Figure 5 -1 .
The default mode is Full Configuration Backhaul unless the Fractional Span box is
checked.
Backhaul Conguration Procedure
Prior to executing Procedure 5 -1 , the information determined and gathered while working
through the System Engineering Section of the UBS Set -up Procedure should be available. This
information documents the intended backhaul configuration for the site and should match the
configuration the OMC -R is expecting to use for the UBS .
F ailure to congure the UBS backhaul correctly with the LMF using the same DS0
congur ation ma y result in the OMC -R being unable to establish communication with
the UBS at cuto v er .
5 -2 68P09283A63 -5
FOA A UG 2007