Specifications
Continuous W a v eform Mode Chapter 4: Acceptance T est Procedures
Continuous Waveform Mode
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■
■
Objective
This test verifies that the UBS frames can generate an unmodulated carrier tone on a single
sector at any single channel number within the supported carrier frequency range of the frame.
Unlock Continuous Waveform Mode
W inLMF must be connected to the UBS frame to be tested and logged in.
Procedure 4 -7 Procedure to Unlock Continuous W a v eform Mode
1
On the menu, click on UBS -> Unlock Continuous W aveform Mode
2
Click the Y es button in the confirmation dialog box.
3
A status report window will appear that shows the result of the action request.
WinLMF will fail to set up Continuous W a v eform Mode for Modem
devices pro visioned in the congur ation les on DMI, but not
ph ysically installed in the fr ame, and for Modem devices under reset.
4
Select tested Sector/Carrier and click Device->X CVR->K ey menu item.
5
In K ey window:
Enter the desired power level [dBm] in the X CVR Gain box
Enter the desired channel in the X CVR Channel box
6
Click the OK button in K ey window .
A status report window will appear that shows the result of the action request.
7
P erform the required testing on the selected Sector/Carrier .
8
Select Sector/Carrier keyed in step 4 and
click Device->X CVR->Dekey menu item.
A status report window will appear that shows the result of the action request.
9
T o perform unmodulated carrier mode test on
other Sector/Carrier repeat procedure from step 4 .
If testing using unmodulated carrier mode is completed follow Lock
Continuous W aveform Mode Procedure
4 -24 68P09283A63 -5