Product Card

1X UBS Macro B T S Optimization/A TP T est Equipment Connection to the LMF
Addressing Methods
Different addressing methods are used for test equipment depending on the type of interface
connection it has. The different addressing methods are described in the following subsections.
GPIB Addresses
GPIB addresses can range from 1 through 30. The LMF will accept any address in that
range, but the numbers entered in the LMF Options window GPIB address box must match
the addresses set in the test equipment. Motorola recommends using 1 for a CDMA signal
generator , 13 for a power meter , and 18 for a communications system analyzer . T o verify
and, if necessary , change the GPIB addresses of the test equipment, refer to the
Setting GPIB
Addresses
sections of Appendix D T est Equipment Preparation .
Serial Connection
This connection type uses a direct serial connection between the test equipment and the
LMF computer platform. The
Anritsu
MT8212B communications test set is an example of
test equipment using this type of connection. There are no specific addressing requirements
for this type of interface.
IP Addresses
T est equipment using the Network connection type use IP addresses to identify them on the
Ethernet LAN . The E7495A and E7495B communications test sets are examples of Network
connection test equipment. Setting the IP address in the test equipment is covered in the
specific test equipment (for example, Agilent E7495) set -up section of Appendix D T est
Equipment Preparation .
68P09283A63 -5 3 -47
FOA A UG 2007