1X UBS Macro B T S Optimization/A TP Cable Calibr ation
Procedure
P erform the following to set cable loss values.
Procedure 3 -22 Setting Cable Loss V alues
1
In the LMF menu bar , click on Util > Edit > Cable Loss
2
In the data entry pop–up window , select
one
of the following:
TX Cable Loss
RX Cable Loss
3
T o add a new channel number , click on Add Row , and click in Channel# and Loss (dBm)
columns and enter the desired values.
4
T o edit existing values, click in the data box to be changed and change the value.
5
T o delete a row , click on the row and then click on the Delete Row button.
6
T o save displayed values, click on the Save button.
7
T o exit the window , click on the Dismiss button.
V alues entered/changed after the Save button was used are not saved.
If cable loss values exist for two different channels, the LMF will interpolate
for all other channels.
Entered values are used by the LMF as soon as they are saved. Logging out
and logging in again is not necessary .
68P09283A63 -5 3 -73