Product Card
1X UBS Macro B T S Optimization/A TP Cable Calibr ation
Procedure
P erform the following to set cable loss values.
Procedure 3 -22 Setting Cable Loss V alues
1
In the LMF menu bar , click on Util > Edit > Cable Loss
2
In the data entry pop–up window , select
one
of the following:
• TX Cable Loss
• RX Cable Loss
3
T o add a new channel number , click on Add Row , and click in Channel# and Loss (dBm)
columns and enter the desired values.
4
T o edit existing values, click in the data box to be changed and change the value.
5
T o delete a row , click on the row and then click on the Delete Row button.
6
T o save displayed values, click on the Save button.
7
T o exit the window , click on the Dismiss button.
V alues entered/changed after the Save button was used are not saved.
• If cable loss values exist for two different channels, the LMF will interpolate
for all other channels.
• Entered values are used by the LMF as soon as they are saved. Logging out
and logging in again is not necessary .
68P09283A63 -5 3 -73
A UG 2007 FOA