Product Card
1X UBS Macro B T S Optimization/A TP Setting and Editing Gener ator Calibr ation Data
Procedure 3 -18 Set or Edit Gener ator Calibr ation Data (Continued)
F or F requency Band fields, select the required frequency band from the
dropdown provided. Selections are made available for the BTS which the LMF
is logged into .
5
T o delete a row , click in the row , and then click the Delete Row button.
6
F or each tab with changes, click the Save button to save the displayed values.
• V alues entered after the Save button was used will not be saved.
• If generator calibration values exist for two different channels assigned to
one frequency band, the LMF will interpolate for all other channels on
this frequency band.
• Entered values will be used by the LMF as soon as they are saved. It is not
necessary to log out and log back into the LMF for changes to take effect.
68P09283A63 -5 3 -63
FOA A UG 2007