Setting and Editing Gener ator Calibr ation Data Chapter 3: LMF Oper ation
Setting and Editing Generator Calibration Data
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
■
■
Generator Calibration Data
Generator calibration data is automatically stored in a generator calibration data file by the
LMF when the generator function of a test equipment item is calibrated using the LMF Util >
Calibrate T est Equipment functions. Stored data values can be edited with this procedure,
or new data can be entered manually for a test equipment item generator function which was
calibrated without using the LMF .
This procedure MUST be used to enter calibr ation data v alues for an y MT8212B which
w as calibrated without using the LMF . F ailure to do this will gener ate incorrect results
for an y RS SI testing performed.
Prerequisites
The LMF is logged into a BTS .
Set or Edit Generator Calibration Data
P erform the following to enter new calibration data or edit existing data.
Procedure 3 -18 Set or Edit Gener ator Calibr ation Data
1
In the LMF menu bar select Util > Edit > Generator Calibration Data .
Result: Generator Calibration Data window appears with tabs for each type of
generator test equipment calibrated using the LMF (for example, the
Anritsu
MT8212B).
2
Click on the tab for the generator with data to be edited or entered.
Result: The tab moves to the forefront.
3
T o edit existing values, click in the data field to be edited and make required changes.
4
T o add a new channel and its data:
1. Click the Add Row button.
2. Click in the field where data is to be entered; for example, F requency Band ,
Channel # , or P ower (dB) .
3. Enter the desired value.
Continued
3 -62 68P09283A63 -5
FOA A UG 2007