Product Card
1X UBS Macro B T S Optimization/A TP T est Set Calibr ation
• Standard Open -Short -Load Components calibration:
Anritsu
22N50 Open/Short, DC to 18 GHz, N(m) connector , 50 ohm
Anritsu
SM/PL precision load, DC -to -4 GHz, 42 dB, N(m) connector , 50 ohm
• Standard InstaCal™ calibration:
Anritsu
ICN50
InstaCal
calibration module, 2 MHz to 4 GHz, N(m) connector , 50 ohm
TX analyzer calibration – P erform the following to calibrate the MT8212B TX analyzer
function..
Procedure 3 -16 Anritsu MT8212B Multi -function T est Set TX Analyz er Calibr ation
1
In the LMF menu bar select Util > Calibrate T est Equipment . Calibrate
Anritsu
MT8212B window appears
2
Click in the radio button in the Calibrate TX Analyzer area.
Result: A black dot appears in the circle.
3
Select the required frequency band from the dropdown list in the F requency Band: box.
The dropdown list in the F requency Band: box is automatically populated
with selections for the base station the LMF is logged into .
4
Enter the channel number to be calibrated in the Channel box.
5
Select the desired calibration method from the dropdown list in the Calibration Method
box.
6
Click OK .
Result: A Directions window is displayed.
7
F ollow the directions provided.
8
When actions required by directions have been completed, click on Continue to close the
Directions window and start the generator calibration process.
Result: A status report window is displayed.
9
Click on OK to close the status report window .
Calibrate CW Generator
Before using the MT8212B test set to perform base station RS SI testing, the test set internal
Continuous W ave (CW) generator must be calibrated.
68P09283A63 -5 3 -59
FOA A UG 2007