Product Card

1X UBS Macro B T S Optimization/A TP T est Set Calibr ation
1. The Agilent E4406A transmitter tester does not support power measurement
level zeroing. Refer to the T est Equipment Calibration section of Appendix F
for E4406A calibration.
2. P ower measurement zeroing and other required calibration procedures for the
Anritsu
MT8212B are included in the Calibrating the
Anritsu
MT8212B on page
3 - 57 subsection below .
Prerequisites
T est equipment to be zeroed has been connected correctly for tests to be run.
T est equipment has been selected in the LMF ( T est Equipment Selection on page 3 - 48 )
and detected.
Procedure
P erform the following to calibrate the test equipment.
Procedure 3 -14 Calibr ate T est Equipment - P ower Measurement Z eroing
1
From the Util menu, select Calibrate T est Equipment from the pull-down menu. A
Directions window is displayed.
2
F ollow the directions provided.
3
Click on Continue to close the Directions window and start the calibration process. A
status report window is displayed.
4
Click on OK to close the status report window .
Calibrating the Anritsu MT8212B
Three types of calibration are required for the MT812B. These are:
Zero out power meter
Calibrate TX Analyzer
Calibrate CW Generator
Procedures for each type of calibration is covered in the following subsections.