Product Card
1X UBS Macro B T S Optimization/A TP T est Equipment Selection
GPIB Interface Test Equipment Manual Selection and Autodetection
Prerequisites - The following must be done before performing these procedures:
• LMF computer and test equipment are both correctly connected to the GPIB box
• T est equipment is turned on
• GPIB addresses set in the test equipment have been verified as correct using the applicable
procedures in Appendix D T est Equipment Preparation .
Manual selection – T est equipment may be selected manually even if it is not connected to
the LMF .
Procedure 3 -8 Manually Selecting T est Equipment - GPIB Interface
1
In the LMF menu bar , select T ools > Options .
Result: The LMF Options window appears.
2
Click on the T est Equipment tab (if not in the forefront).
3
Click the GPIB radio button in the Connection T ype area.
Result: A black dot appears in the circle.
4
Click the COM radio button in the GPIB/COM settings area.
Result: A black dot appears in the circle.
5
Select the correct LMF computer serial port from the P ort: pick list (normally COM1 )
(Refer to the T est Equipment Connection to the LMF on page 3- 45 section of this chapter).
6
In the GPIB T est equipment area click the checkbox(es) of the test equipment being
used.
Result: Checkmarks appear in the boxes clicked on.
7
If one is not already displayed, type the GPIB address for each checked
piece of test equipment in the corresponding box labeled GPIB .
Recommended Addresses
1 = CDMA Signal generator
13 = P ower Meter
18 = CDMA Analyzer
When the test equipment items are manually selected, the CDMA analyzer is
used only if a power meter is not selected.
Continued
68P09283A63 -5 3 -49
FOA A UG 2007