Product Card

1X UBS Macro B T S Optimization/A TP T est Equipment Set Up
Supported Test Equipment
Optimization and A TP testing for CDMA2000 1X sites or carriers may be performed using the
following test equipment:
Advantest R3267 Analyzer with Advantest R3562 Signal Generator
Agilent E4406A with E4432B Signal Generator
Agilent 8935 series E6380A communications test set (formerly HP 8935) with option 200
or R2K and with E4432B signal generator for 1X FER
Agilent E7495A or Agilent E7495B communications test sets
The E4406A/E4432B pair , or the R3267/R3562 pair , should be connected together using a GPIB
cable. In addition, the R3562 and R3267 should be connected with a serial cable from the Serial
I/O to the Serial I/O . This test equipment is capable of performing tests in both IS -95 A/B mode
and CDMA 2000 mode if the required options are installed.
T o prev ent damage to the test equipment, all TX test connections must be through the
directional coupler and in -line attenuator as shown in the test setup illustr ations.
Optional test equipment
A spectrum analyzer , such as the HP8594E, and a signal generator supporting the required
frequency ranges can be used to perform manual cable calibration.