Product Card
1X UBS Macro B T S Optimization/A TP Download Code to UBS
The UBS code load should always be synchronized with the download from the
OMC -R before leaving the UBS site. Refer to Reset All Devices and Initialize Site
Remotely on page 5 - 8 for the procedure to do this.
Procedure 3 -5 Download Code
1
In the menu bar of the Local T erminal BTS window , select BTS > Download Code...
2
If prompted that the “F ollowing operation may overwrite NECB, NECJ , LIF , and calibration
files on the BTS”, click Y es .
3
In the dialog box which appears, if the Use Local FTP server checkbox is not checked, click
in it to select this option.
Result: A check mark will appear in the box.
4
In field labeled Software version enter the <software_release#> as specified in the
prerequisite section (for example, 2.19.0.0.20).
5
If a “clean download” is required (download every file, even if they are the same as those
currently installed on the UBS), click in the P erform clean load checkbox.
Result: A check mark will appear in the box.
6
Click Ok to start the download.
Code download can require up to 40 minutes to complete.
7
When the download is complete, click Ok to close the status report window .
When the code load is complete, the UBS will re–start, and the LMF will lose
contact with the UBS .
8
Log the LMF into the UBS again.
68P09283A63 -5 3 -31
FOA A UG 2007