Product Card
1X UBS Macro B T S Optimization/A TP Using WinLMF
CLI Format Conventions
The CLI command can be broken down in the following way:
• verb
• device including device identifier parameters
• switch
• option parameters
keywords
equal signs
parameter values
Spaces are required between the verb, device, switch, and option parameters. A hyphen is re-
quired between the device and its identifiers. The following is an example of a UBS CLI command:
configure sc -<bts#> -<sector#> -<carrier#> pgain=<pgain#>
mdm_slot=<mdm_slot#> ce=<ce#> [pnoffset=<pnoffset#>]
Refer to the
W inLMF CDMA CLI Commands – 68P09275A12
manual for further information
on CLI commands and their use.
Logging into a UBS
Logging into a UBS establishes a communications link between the UBS and the LMF . An LMF
session can be logged into only one UBS at a time.
Prerequisites
Before attempting to login to a UBS , ensure the following have been completed:
• The LMF is properly connected to the UBS (see Figure 3 -2 )
• The LMF application program is correctly installed and prepared
• Preparing the LMF for Connectivity and Configuring the Controller of UBS procedures
are completed
• The LMF computer was connected to the UBS before starting the W indows operating
system and LMF software. If necessary , restart the computer after connecting it to the
UBS in accordance with Procedure 3 -3 and Figure 3 -2 .
• When the PC has completed startup, click on WinLMF with UBS Support icon Figure 3 -3
to bring up the Local T erminal window ( Figure 3 -4 )
• IP Address is 128.0.0.xxx
• Netmask address is 255.255.255.128
• BlackICE or other similar process is disabled
• W indow
Internet Connection Firewall
and other firewall programs should be disabled
• Java Runtime Environment (JRE) is installed and version matched
68P09283A63 -5 3 -9
FOA A UG 2007