Manual
P ack et B T S start -up procedures Chapter 3: R eference Procedures P erformed A t OMCR
Procedure 3 -3 R estore site signaling oper ations procedure for a pack et B T S
(Continued)
15
In this step, use the values recorded in step 4 of Procedure 3-2 to answer the
prompts for the EDIT BTS REDIRECT command, except for <recordtype> , enter 2 .
Restore the values of all REDIRECT parameters by entering the following command at the
prompt:
omc-000000> EDIT BTS-<bts#> REDIRECT !
The system prompts to enter each command parameter one at a time. Answer the
prompt in the following order:
The following speciļ¬ed values are consistent with the original example. Actual
values may vary .
<accolc0> enter N , <accolc1> enter N , . . . <accolc15> enter N
<returniffail> enter N
<recordtype> enter 2
<expectedsid> enter 0
<ignorecdma> enter N
<sysordering> enter CUSTOM
<rotatetimer> enter 4
16
A fter all parameters are entered, the system displays the command to be sent and the prompt
below . V erify the command syntax is correct.
omc-000000>Accept [yes/no]?
17
A t the prompt shown in step 16 , enter Y to accept the command or N to go bottom and enter
the correct value(s).
18
Enter the following command at the prompt to display the status of the signaling REDIRECT
parameters:
omc-000000> DISPLAY BTS-<bts#> REDIRECT
19
Ensure that the values in the system display response matches with the values input by the
operator in step 15 .
3 -12 68P09283A64 -3
FOA SEP 2007