Manual

1X UBS Macro B T S FRU P ack et B T S shutdown procedures
Procedure 3 -2 Shutdown site signaling functions procedure for a pack et B T S
(Continued)
19
The system prompts to enter each control parameter value one at a time. Skip through the
prompts until reaching the following, and enter the parameter shown:
<globalredirect> ENABLE
(This will force the Global Service Redirect Message to be broadcast on all of the sector
paging channels at the BTS .)
20
When the system displays the values of the control parameters and the following prompt,
verify that only the GLOBALREDIRECT value changed.
omc-000000>Accept [yes/no]?
21
If only the GLOBALREDIRECT value changed, enter Y to accept the change.
(When the change is accepted, the Global Service Redirection Message is sent over the sector
paging channels. All subscribers are redirected away from the BTS and onto a different
system or CDMA carrier channel. This effectively shuts down the BTS .)
22
V erify that the CONGESTCONF Global Redirect is enabled for each carrier at the BTS by entering
the following command at the prompt:
omc-000000> DISPLAY BTS-<bts#> CONGESTCONF
23
Enter the following command at the prompt to display the status of all devices at the BTS:
omc-000000> DISPLAY BTS-<bts#> STATUS
24
Record all devices that are listed as OOS_AUTOMATIC in the response to step 23 .
This information will be used for later reference when restoring site signaling
operations.
25
W ait for three minutes to allow any active calls to terminate then go the next step.
26
Lock/disable the BTS by entering either of the following commands at the prompt:
omc-000000> DISABLE BTS-<bts#> UNC
omc-000000> LOCK BTS-<bts#>
68P09283A64 -3 3 -9
FOA SEP 2007